shirley@deruitest.com

+86 155 8032 7593

EN

EN

CN

Vibration Shaker and Simulated Transportation Tester

Floor-standing 10-station suction machine (100ml) DR-SM010

Equipment OverviewThis device is designed for measuring the draw resistance of finished electronic cigarettes and is widely used in the quality control and inspection of electronic cigarette productio ...

Inquire Now
Description

Equipment Overview

This device is designed for measuring the draw resistance of finished electronic cigarettes and is widely used in the quality control and inspection of electronic cigarette production. It operates based on the principle of simulating manual smoking with a piston. The specific operation process is as follows: First, connect the electronic cigarette to be tested to the test position with a tube. At this point, the piston in the device simulates the manual smoking action and draws a fixed flow rate (for example, 17.5 ml/s) of air into the electronic cigarette. During this process, a certain vacuum pressure, that is, the draw resistance, will be generated at the inhalation end of the electronic cigarette. The tester will measure this pressure in real time, which is the real-time draw resistance. In this way, the draw resistance characteristics of the electronic cigarette can be accurately measured. During the test, the product can be charged. 

Product Features and Characteristics

1. It can test real-time draw resistance, the presence or absence of smoke or smoke concentration (optional), and stable draw resistance. It can also draw real-time curves of puffing speed, real-time draw resistance, and smoke concentration.

2. It can choose trapezoidal wave puffing or sinusoidal wave puffing mode.

3. It can choose cycle testing or single testing mode.

4. Each testing station is equipped with a USB charging port to power the product.

5. It can set judgment parameters to determine whether the draw resistance or smoke of each test is qualified.

6. It has the function of storing and exporting test data, and can query, generate test data and charts, and export them, which is convenient for customers to analyze the performance of the tested electronic cigarettes.

7. (Optional) The product fixture and the thumb cylinder for lighting are flexible and adjustable, making it convenient to test different models of electronic cigarettes.

8. Optional function keys. Fixture

Presence or absence of smoke (anti-dry burn)

Smoke concentration

Instrument parameters

Item NameSpecifications
Dimensions1100(L)×700(W)×1500(H) mm
Power SupplyAC 220V (±10%), 50Hz
Display Configuration10.1-inch screen
Operating SystemIndependently developed
Air Supply0.4~0.8 MPa
Suction ModeSine wave / Trapezoidal wave
Key FunctionEach station with independent fixture and cigarette-lighting thumb cylinder (optional)
Suction Speed0.1~60 ml/s adjustable
Suction Volume1~100 ml (accuracy ±0.1%)
Interval Per Puff0.1~999 s adjustable
Suction & Discharge Interval0.1~999 s adjustable
Total Puff Count1~999999 puffs adjustable
Negative Pressure Sensor0 ~ -3000 Pa; 0.2% FS
Other FunctionsUpper & lower limit parameters settable, automatic qualification judgment