shirley@deruitest.com

+86 155 8032 7593

EN

EN

CN

Vibration Shaker and Simulated Transportation Tester

Triple-head dual-station resistance and suction testing instrument DR-CD012

Dear partners, bid farewell to the cumbersome testing procedures and let's step into the new era of intelligent testing together! Today, I would like to introduce to you a multi-functional wonder - th ...

Inquire Now
Description

Dear partners, bid farewell to the cumbersome testing procedures and let's step into the new era of intelligent testing together! Today, I would like to introduce to you a multi-functional wonder - the "Electronic Cigarette Triple-Function Dual-Station Resistance Testing Instrument".

Usage scenarios:

Whether you are in the production workshop or the research and development laboratory, this resistance testing instrument can provide you with all-round support. It can monitor the resistance data of electronic cigarettes in real time, allowing you to easily grasp the quality status of each batch of products. Here are some typical application scenarios:

Production stage: On the production line, quickly test the resistance of electronic cigarettes to ensure that the quality of each product meets the standards.

Research and development testing: During the research and development process, accurately measure the resistance data of different models of electronic cigarettes to assist in optimizing product design.

Quality inspection: In the finished product inspection stage, efficiently screen out non-conforming products to improve overall quality.

Triple-Function Dual-Station Resistance Testing Instrument:

Dual-station design: Test two products simultaneously to increase testing efficiency and save valuable time.

Triple-function integration: Integrate resistance, airflow, and temperature testing functions. With one instrument in hand, you can easily handle various testing needs.

User-friendly interface: An intuitive and easy-to-understand operation interface makes the testing process simple and fast.

Precise and reliable: Equipped with high-precision sensors to ensure the accuracy and reliability of test data. 

Features of the Triple-Position Dual-Station Resistance and Output Current Testing Instrument

1. Two stations test simultaneously. The power cord is automatically inserted to charge the product. After the charging is qualified, the resistance and output current tests are conducted to determine if they are normal.

2. The machine automatically identifies whether the charging current is within the required range using the rated input voltage (generally 5V, adjustable) and the rated current (generally 2A, adjustable). If the charging current of the product is within the required range, it is OK and a green light should be on at the corresponding station; if the charging current is not within the set range, it is NG and an alarm buzzer and a red light should be on at the non-conforming station. If both stations are non-conforming, both stations should have an alarm buzzer and a red light on. The charging detection insertion and removal mechanism should use a flexible structure and not be hard-inserted or hard-pulled. In any case, the current value during charging should be displayed (current size display).

3. After the test starts, it is checked if there is smoke. If there is no smoke from the product, the machine can automatically identify it and an alarm buzzer and a red light should be on at the non-conforming station. If both stations are non-conforming, both stations should have an alarm buzzer and a red light on. If the product can produce smoke normally, it is OK and a green light should be on at the corresponding station.

4. During the resistance test, the output current or voltage (current and voltage can be switched to display or displayed simultaneously) is also tested. For products with double mesh heating wires, the output current needs to be tested. If one group of a product is qualified and the other is NG, the machine can automatically identify it and an alarm buzzer and a red light should be on at the non-conforming station.

5. The resistance and smoke test requires the free setting of the suction time and the number of suction times.

6. The charging test of the two stations and the smoking test of the two stations can be freely shielded and freely selected to be turned on.

7. The loading and unloading actions are manually performed by the operator.

8. The product completion time is ≤ 6 seconds per cycle (excluding the time for manual product handling).

9. Charging protocol function detection: The charger has its own protocol function and can self-check whether to charge or not when connected to the product:

1: Charging, OK if within the voltage and current range.

2: Not charging. NG if not charged within the detection time. 

Parameters of the Triple-Head Dual-Station Resistance and Suction Testing Instrument

head>
Item NameSpecifications
ModelCD012
Power SupplyAC 220V (±10%), 50Hz
Stations2 independent channels
Voltage Sensor0~10V; 0.2% FS (True RMS sensor)
Negative Pressure Sensor0~-3000Pa; 0.2% FS
Resistance1/0.2Ω; ±2%
Suction Speed0.1~60 ml/s adjustable
Suction Volume1~100 ml (accuracy ±0.1%)
Interval Per Puff0.1~999 seconds adjustable
Suction & Discharge Interval0.1~999 seconds adjustable
Total Puff Count1~999999 puffs adjustable
Judgment & AlarmAutomatic judgment; sound + buzzer alarm
Other Features2 plastic frames for smoke collection
Other FunctionsA. Silent operation – new pinch valve technology
B. Smoke sensor
C. Data export function
Upper and lower limit parameters settable, automatic qualification judgment
Data StorageLocal storage for 1000 groups of data, support U-disk export; auto-save to U-disk when inserted
Dimensions530×450×470 mm (L×W×H) (for reference only, subject to actual production)

1728722268428959