Room Temperature Tape Retention Tester (5 Stations)

2026.09.05 11:10:38

This 62-second video introduces the DERUI DR-B301 five-station room-temperature tape retention (holding power) tester manufactured by Guangdong DERUI Testing Equipment Co., Ltd. It demonstrates the static-load test method: one-inch-wide adhesive tape strips are bonded to SUS#304 stainless-steel test plates, pressed with a 2 kg standard roller, and loaded with 1000 g weights so that each station automatically records how long the tape stays adhered before it detaches. The tester evaluates the holding power and lasting adhesion of pressure-sensitive tapes, labels and sticker products under room-temperature conditions.

DR-B301Equipment model
5Test stations with independent timers
1000 gLoad per station (±10 g, incl. loading plate)
99999.9 hTimer range, auto-retention

What This Holding Power Video Shows

Test bench and stations

  • Five-station configuration for parallel testing of up to five specimens

  • Five timers with automatic retention of the elapsed test time

  • Five SUS#304 stainless-steel test plates and five matching loading plates

Sample preparation and mounting

  • One-inch-wide (25.4 mm) tape strips bonded to the cleaned test plate

  • 2 kg standard roller presses each specimen at 300 mm/min over three return passes

  • The loaded test plate is hung on the tester and the standard weight is attached

Loading and timing

  • 1000 g ± 10 g weight per station, the weight including the loading plate

  • When the tape detaches from the plate, the timer automatically retains the elapsed time

  • The test evaluates the lasting adhesion and creep resistance of pressure-sensitive adhesives

How a Room-Temperature Retention Test Works

Step 1 - Prepare

Cut the adhesive tape into one-inch-wide (25.4 mm) strips of the required length.

Step 2 - Bond

Clean the SUS#304 test plate, bond the specimen over the required area, and press it with the 2000 g ± 50 g roller at 300 mm/min for three return passes. Apply only the mass of the roller, without additional force.

Step 3 - Load

Hang the test plate vertically on the tester and attach the standard weight (1000 g ± 10 g, including the loading plate) to apply a constant shear load.

Step 4 - Record

When the tape separates from the plate, the station timer automatically retains the elapsed time. Five specimens are tested and recorded independently at the same time.

Interpretation note: A longer time-to-detachment indicates stronger holding power. Compare results only when the same method, bonded area, load, pressing and conditioning are used.

DR-B301 Specifications

ParameterSpecificationSelection note
ModelDR-B301Confirm the complete model designation on the quotation.
Test conditionRoom temperature (ambient)No heating function in this model; select a thermostatic tester if an elevated-temperature method is required.
Test stations5Five timers, five test plates and five loading plates supplied.
Test platesSUS#304 stainless steel, 5 pcs; thickness 1.5-2.0 mm, width 40-50 mm, length 60-125 mmPlate dimensions are selected per the invoked standard.
Pressing roller2000 g ± 50 gRolled over the specimen at 300 mm/min, three return passes.
Weight (load)1000 g ± 10 g per station, including the loading plateConfirm the load value required by the applicable standard.
TimerAutomatic retention of elapsed time; range up to 99999.9 h (or minutes, settable); 5 groupsConfirm the required units and resolution for your records.
External dimensionsApprox. 530 × 250 × 650 mm (L × W × H)Confirm clearance and benchtop space.
Machine weightApprox. 32 kg-
Power supplyRequired for the electronic timers - confirm the voltage and frequency with the quotationThis machine has no heating element.
Compliant standardsGB/T 4851, JIS Z0237, CNS 11888, PSTC-7Confirm the exact edition and procedure for your acceptance criteria.
Method note: Holding power is a method-dependent result, not a fixed machine rating. The same tester can produce different time values under different bonded areas, loads, pressing and conditioning - always compare results obtained under the same test method and conditions.

Where Room-Temperature Holding Power Testing Is Used

  • Adhesive tape manufacturers - packaging, masking, double-sided, electrical and specialty tapes are checked for their ability to stay adhered under a sustained load.

  • Label and sticker producers - self-adhesive labels, sticker and film products are checked for lasting adhesion so they do not peel or creep in service.

  • Adhesive and PSA formulators - holding power and creep-resistance data support formulation development and batch-to-batch consistency.

  • Quality inspection and incoming QC - holding power testing is a routine part of adhesive-product quality inspection in the adhesive industry.

Room-Temperature vs. Thermostatic Holding Power Testers

<thead>
Selection factorRoom-temperature tester (DR-B301)Thermostatic (oven-type) tester
Test temperatureAmbient / room temperatureControlled temperature, typically elevated
Typical useRoom-temperature holding power and lasting-adhesion testsHeat-resistance and high-temperature shear behaviour of tapes and adhesives
ConstructionSimple test stand with plates, weights and electronic timers; no heating systemAdds a heated cabinet with temperature control
Complexity and costSimpler structure, easier operation, more economicalHigher complexity and cost
Best choice depends onTape type, backing, adhesive system, the standard invoked and the temperature required by the acceptance test. Confirm the thermostatic model's specification separately if an elevated-temperature method applies.

Standards and Test-Plan Compatibility

The DR-B301 is designed for holding power (static-load) testing of pressure-sensitive adhesive tapes in accordance with GB/T 4851 (China), JIS Z0237 (Japan), CNS 11888 (Taiwan) and PSTC-7 (Pressure Sensitive Tape Council), as stated in the product datasheet. The same physical test - shear adhesion of pressure-sensitive tapes under a constant load - is also described by international procedures such as ASTM D3654 (room-temperature procedure) and ISO 29863; compatibility with any of these should be confirmed against the exact edition and procedure invoked.

Equipment capability alone does not prove compliance with every standard. Confirm the applicable edition and procedure, then verify performance with your actual tape, plate preparation, load and conditioning method.

Information Required for a Quotation

  • Tape or label type, backing material and adhesive system

  • Specimen width (e.g. 1 inch) and bonded area per the standard

  • Required test temperature (room temperature vs. elevated)

  • Required load per station and pressing procedure

  • Number of stations needed

  • Applicable standard, acceptance limits and required minimum holding time

Frequently Asked Questions

What does the DR-B301 measure?

It performs the static-load (holding power) test for tape adhesion: under a defined load at room temperature, it automatically times how long a tape specimen remains adhered to a stainless-steel test plate, to evaluate the persistence of the adhesive bond.

How many samples can be tested at once?

The DR-B301 is a five-station configuration. Five specimens are tested simultaneously, and each station's timer retains its result independently when the tape detaches.

What standards does it comply with?

Per the product datasheet, the DR-B301 is designed in accordance with GB/T 4851, JIS Z0237, CNS 11888 and PSTC-7.

Does the DR-B301 have a heating system?

No. It is a room-temperature tester with no heating element. Power is needed only for the electronic timers - confirm the supply voltage and frequency with the quotation.

How is the specimen prepared and loaded?

One-inch-wide tape strips are bonded to SUS#304 plates and pressed with a 2000 g ± 50 g roller at 300 mm/min for three return passes; then a 1000 g ± 10 g weight (including the loading plate) is applied to each specimen.

Is this tester the same as a constant-temperature (thermostatic) model?

No. The DR-B301 operates at room temperature and has no heating function. The YouTube title of this video uses the words "Constant Temperature", but the video description states the test is performed under room-temperature conditions - confirm which model and temperature range your test plan requires before ordering.

Video Summary

This 62-second English-language video presents the DERUI DR-B301 five-station room-temperature tape retention tester. It demonstrates the weight-loading (static-load) test: one-inch-wide tape strips are bonded to SUS#304 stainless-steel test plates and pressed with a 2 kg standard roller at 300 mm/min over three return passes; 1000 g weights (including loading plates) apply a sustained load, and each station automatically retains the time until the tape falls off. The tester evaluates the holding power and lasting adhesion of pressure-sensitive adhesive tapes, labels and sticker products under room-temperature conditions.

Need a Holding Power Tester Proposal?

Send the tape type, specimen size, bonded area, test temperature, load, number of stations and applicable standard to Guangdong DERUI Testing Equipment Co., Ltd. for a configuration review and quotation.


Processed in 0.321008 Second , 406 querys.