The automatic turret type Vickers hardness tester can meet the basic requirements of Vickers hardness testing. The upgraded turret can automatically switch the eyepiece and indenter, avoiding instrume ...
The automatic turret type Vickers hardness tester can meet the basic requirements of Vickers hardness testing. The upgraded turret can automatically switch the eyepiece and indenter, avoiding instrument damage caused by human error and also improving efficiency. It adopts a 7-inch LCD touch screen, which can provide more measurement data.
Main functions and features:
1.The optical system designed by the optical engineer not only provides clear images but can also be used as a simple microscope. It features adjustable brightness, comfortable vision, and is not prone to causing fatigue even after prolonged operation.
2. The 7-inch touch screen can display the test method, test force, upper and lower limits of hardness value, measured indentation length, hardness value, test force holding time, measurement times, and can input year, month, and date. It can also display test results and data processing, etc.
3. The system is equipped with a built-in calibration function. For each test force level, the input error can be manually adjusted using the calibration instrument.
4. Adjustable range of optical system brightness: 0 - 100.
5.It can store up to 100 sets of test data, and display the average value and the number of tests on the main interface.
6. The test force unit can be manually selected and converted. The conversion units are: (Kgf, N)
7.The main interface can simultaneously display 4 conversion scales and can be switched among: national standard, American standard and international standard. A total of 18 measurement scales can be converted: HRA, HRB, HRC, HRD, HRE, HRF, HRG, HRH, HRK, HR15N, HR30N, HR45N, HR15T, HR30T, HR45T, HV, HK, HBW.
8.Both objectives can directly measure hardness.
9. The upper and lower limit measurement ranges can be set and displayed on the main measurement interface.
10. Test data can be directly exported via USB.
11. The measurement scale can be converted to HK Knoop hardness.
12. The operating system can be switched between Chinese and English.
13. An optional built-in printer is available. Test data can also be output via USB to a USB flash drive for storage and analysis.
14.The HVT-5Z model can achieve the position switching among observation, testing and measurement, which is completed by the automatic turret.
15. The cast aluminum shell is formed in one piece with stable structure and no deformation. It is coated with pure white automotive paint, which is of high grade and has strong scratch resistance. It remains as bright as new even after years of use.
16.Our company has the ability to independently research and develop, design, and produce and process. We offer lifetime parts replacement and maintenance and upgrade services for our machines.
Main uses and application scope:
1.Steel, non-ferrous metals, metal foils, hard alloys, metal sheets, microstructure, carbonization;
2. Carburizing, nitriding and decarburizing layers, surface hardening layers, electroplating layers, coatings, heat treatment;
3. Glass, wafers, ceramic materials;
Technical parameters:
| Parameter Name | Parameter Data |
|---|---|
| Vickers Hardness Scales | HV0.3, HV0.5, HV1.0, HV2.0, HV3.0, HV5.0 |
| Display | 5-digit hardness value, 4-digit diagonal length (D1, D2), dwell time, test times, average value, standard deviation, return |
| Test Force (Kgf) | 0.3, 0.5, 1.0, 2.0, 3.0, 5.0kgf |
| Loading Control | Automatic (loading/dwell/unloading) |
| Test Force Dwell Time (s) | 1~99 |
| Optical Channel | Dual optical channels (eyepiece and CCD camera) |
| Optical System | Objective lens: 10×, 20× (changeable to 40×); Eyepiece magnification: 10×; Total magnification: 100×, 200×; Measuring range (μm): 400; Resolution (μm): 0.5 |
| Hardness Measurement Range | (5-3000)HV |
| XY Stage | Size (mm): 100×100; Travel range (mm): 25×25; Minimum reading (mm): 0.01 |
| Maximum Specimen Height (mm) | 165 |
| Maximum Specimen Width (mm) | 130 (distance from indenter centerline to machine wall) |
| Data Output (Optional) | Built-in printer; test data can also be saved/analyzed via USB to U-disk |
| Power Supply | AC220V/50Hz |
| Overall Dimensions (mm) | 585×200×630 |
| Weight (kg) | 42 |
Standard configuration:
| Name | Quantity |
|---|---|
| Main Unit | 1 set |
| Weights | 3 pcs |
| Cross Measuring Stage | 1 pc |
| Flat Clamping Stage | 1 pc |
| Leveling Screws | 4 pcs |
| Power Cord | 1 pc |
| 10× Measuring Eyepiece | 1 pc |
| Standard Vickers Hardness Blocks | 2 pcs |
| Spare Fuse (2A) | 2 pcs |
| Product Certificate | 1 copy |
| Operation Manual | 1 copy |