1.Workstation: 128 PCS 2. The product area is on the 8th floor and the power supply area is also on the 8th floor. The clear height between each floor is 170mm. The bottom floor is 240mm from the ...
1.Workstation: 128 PCS
2. The product area is on the 8th floor and the power supply area is also on the 8th floor. The clear height between each floor is 170mm. The bottom floor is 240mm from the ground and the top floor is 1500mm from the ground. The width of the product area is 200mm (the installation of the layer board can be optional). There are 16 products on each floor, with 8 floors in total. 128 products can be aged at one time.
3. Place the product on one side only, and install the charging switch power supply on the back.
4. Module control mode: RS485 communication mode, computer control, each cabinet is independently controlled, multiple units can be operated by one computer (one computer can control 8 machines)
5. 16 charging data acquisition boards;
6. Module isolation method: Adopting photoelectric isolation (communication and power supply isolation)
7. Power supply quantity: Optional: Maximum charging 0.5A: Install 2 5V40A switching power supplies; Maximum charging 1A: Install 4 5V40A switching power supplies; Maximum charging 2A: Install 8 5V40A switching power supplies; Maximum charging 3A: Install 8 5V60A switching power supplies;
8. Charging mode: Constant voltage charging
9. Voltage acquisition: DC 0-25V, ±1%RD + 30mV
10. Voltage resolution: 10 mV
11. Current collection: DC 0-4A, ±1%RD + 3mA;
12. Current resolution: 1 mA
13. Scanning speed: 10 ms/ch
14. Charging interface type: USB female socket, equipped with LED status indicator. Standby: light off; charging: red light on; charging completed: red light off, green light on; charging abnormal: red light flashing.
15. Software data export formats: EXCEL, TXT documents
16. Cooling method: Air cooling, top exhaust fan
17. Computer control: User-provided or optional
18. Equipment power supply: AC 220V
19. Dimensions of the structure: 1780*650*1880mm (LxWxH)
20. Equipment Grounding: Grounding protection is essential.